Cr_Ptimer Command; Cr_Tempwarn Command - Sanyo PLC-XL51 - 2700 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XL51 - 2700 Lumens:
Table of Contents

Advertisement

PLC-XL51 Expand Serial Command Functional Specifications

9.12.5 CR_PTIMER Command

Command
"CR_PTIMER"[CR]
Details
Get status of Presentation Timer
Acceptable
Response
%a
Unacceptable

9.12.6 CR_TEMPWARN Command

Command
"CR_TEMPWARN"[CR]
Get the temperature inside a projector and its condition if it is abnormal
temperature or close to abnormal temperature
Details
If there are several sensors installed, it is possible to get information from all the
sensors at once.
Acceptable
%a
Response
%b
%c
Unacceptable
"000_%a"[CR]
"ON" -------------------- Presentation timer is in operation
"STOP" ----------------- Presentation timer is paused
"OFF" ------------------- Presentation timer is not operating
"?"[CR]
"000_%a_%b_%c"[CR]
%a -------------------- Sensor 1 status
%b -------------------- Sensor 2 status
%c -------------------- Sensor 3 status
"W" ---- Approach or reach abnormal temperature
(dangerous temperature)
"S" ---- Far from abnormal temperature (safe temperature)
"N" ---- Sensor detects no abnormal temperature
[Example]
"S_W_S"[CR] means Sensor 1 detects safe temperature, Sensor
2 detects abnormal temperature and Sensor 3 detects safe
temperature
Note) When the temperature difference between Sensor 1 and 3
reaches specific value, some of the models detect it as Abnormal
temperature. In this case, the 3rd data shows if the temperature
difference between Sensor 1 and 3 is dangerous state or not. The
3rd data means temperature abnormality due to Sensor 3
When abnormal temperature is not detected by sensor, "N" (No
connection with temperature abnormality) is returned.
"?"[CR]
61/63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xga ultra short-throw plc-xl51

Table of Contents