Table 8.3-1 PWC pulse width control register 1 (PCR1) bits
Bit
Bit 7
EN:
Counter operation
enable bit
Bit 6
Unused bit
Bit 5
IE:
Interrupt request enable
bit
Bit 4
Unused bits
Bit 3
Bit 2
UF:
Underflow (01
-->
H
00
) interrupt request
H
flag bit
Bit 1
IR:
Measurement
completion interrupt
request flag bit
Bit 0
BF:
Buffer full flag bit
For the interval timer function:
Writing "1" to this bit starts the counter to count down from the PWC reload buffer register
(RLBR) value. Writing "0" to this bit stops the counter operation.
For the pulse width measurement function:
Writing "1" to this bit enables measurement. The counter starts to count down from "FF
detection of the specified edge on the measurement pulse. Writing "0" to this bit stops the
counter operation.
Note:
If operation is disabled (EN = "0") during measurement in pulse width measurement mode, the
counter stops but the value is not transferred to the RLBR register. Restarting operation (EN =
"1") sets the counter value to "FF
The read value is indeterminate.
Writing to this bit has no effect on the operation.
This bit enables or disables an interrupt request output to the CPU.
An interrupt request is output when both this bit and one or more of the interrupt request flag bits
(UF, IR, and BF) are "1".
The read value is indeterminate.
Writing to these bits has no effect on the operation.
This bit is set to "1" when the counter underflow (01
An interrupt request is output when both this bit and the interrupt request enable bit (IE) are "1".
Writing "0" clears this bit. Writing "1" has no effect and does not change the bit value.
Notes:
When the interval timer function is active, the PWC inverts the timer output bit (PCR2: TO) if
the counter underflow (01
from the RLBR register value. In one-shot timer mode, the counter operation automatically stops
(EN = "0").
If the counter underflow (01
width measurement function, this bit is set to "1" and counter operation continues.
• For the pulse width measurement function:
This bit is set to "1" when the pulse width measurement is completed.
An interrupt request is output when both this bit and the interrupt request enable bit
(IE) are "1".
• Writing "0" clears this bit. Writing "1" has no effect and does not change the bit value.
• For the interval timer function:
The bit has no meaning.
• For the pulse width measurement function:
This bit is an interrupt request flag and is set to "1" when a measurement value is
present in the RLBR register.
An interrupt request is output when both this bit and the interrupt request enable bit
(IE) are "1".
This bit is set to "1" when pulse width measurement completes and cleared to "0" when
the measurement value is read from the RLBR register.
This bit is read-only. The write value has no meaning and has no effect on the
operation.
• For the interval timer function:
This bit has no meaning.
CHAPTER 8 PULSE WIDTH COUNT TIMER (PWC)
Function
" then enables operation.
H
--> 00
H
--> 00
) occurs. In reload timer mode, counting down continues
H
H
--> 00
) occurs while measuring a long input pulse in the pulse
H
H
" on
H
) occurs.
H