Discovery ELAN Setup Screen
Figure 3-21 ATM Discovery ELAN Setup Screen
The following definitions describe each of the ATM Discovery ELAN Setup screen fields:
Index (Read-only)
Displays the number assigned to this ELAN. A total of 16 discovery ELANs can be assigned to the
VHSIM2-A6DP.
ELAN Name (Modifiable)
Used to enter the name of the discovery ELAN that the VHSIM2-A6DP will join when the
discovery ELAN becomes enabled.
Mode (Toggle)
Used to toggle between "Master" and "Slave". When the VHSIM2-A6DP is configured to be in
"Master" mode, it will accept connections from all other VHSIM2-A6DPs in the Discovery
ELANs it belongs to. When the VHSIM2-A6DP is configured to be in "Slave" mode, it will only
accept connections from other VHSIM2-A6DPs configured to be in "Master" mode.
Status (Toggle)
Used to toggle between Enabled and Disabled. The Status field is used to direct the
VHSIM2-A6DP to either join the specified discovery ELAN (Enabled), or disconnect from the
specified discovery ELAN (Disabled).