Signalling Screen

3.17 SIGNALLING SCREEN

The Signalling screen is used to set the parameters for all SVCs, to view the Integrated Local
Management Interface (ILMI) Physical Address, view the current version of UNI being used by
the VHSIM2-A6DP, to disable ILMI and UNI, and to restart ILMI and UNI.
To access the Signalling screen from the ATM menu screen, perform the following steps:
1. Use the arrow keys to highlight the SIGNALLING menu item on the ATM menu screen.
2. Press ENTER. The Signalling screen,
Figure
3-19, displays.
Figure 3-19 Signalling Screen
The following list explains each of the Signalling screen fields:
ILMI Status (Selectable)
Used to enable or disable the ILMI. This field contains the following options: Auto Configure
Enabled, Enabled, and Disabled. The default for this field is Auto Configure Enabled. For
instructions on how to change the ILMI status, refer to
Section
3.17.1.
ILMI State (Read-Only)
This read-only field displays the current status of the ILMI. For ILMI to be operational this field
should read "Verifying" if the ILMI Status field is set to "AutoConfig Enabled" or "Enabled".
Local Management
3-57