Call Progress Tones Template
Table 20
#Busy
[CALL PROGRESS TONE #5]
Tone Type=3
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=20
High Freq Level [-dBm]=32
First Signal On Time [10msec]=50
First Signal Off Time [10msec]=50
Second Signal On Time [10msec]=50
Second Signal Off Time [10msec]=50
#Reorder tone
[CALL PROGRESS TONE #6]
Tone Type=7
Low Freq [Hz]=480
High Freq [Hz]=620
Low Freq Level [-dBm]=24
High Freq Level [-dBm]=24
First Signal On Time [10msec]=25
First Signal Off Time [10msec]=25
Second Signal On Time [10msec]=25
Second Signal Off Time [10msec]=25
#Confirmation tone
[CALL PROGRESS TONE #7]
Tone Type=8
Low Freq [Hz]=350
High Freq [Hz]=440
Low Freq Level [-dBm]=20
High Freq Level [-dBm]=20
First Signal On Time [10msec]=10
First Signal Off Time [10msec]=10
Second Signal On Time [10msec]=10
Second Signal Off Time [10msec]=10
#Call Waiting Tone
[CALL PROGRESS TONE #8]
Tone Type=9
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=20)
High Freq Level [-dBm]=32
First Signal On Time [10msec]=0
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=30
Second Signal Off Time [10msec]=900
Format of the Ringing Definition
The ringing pattern configures the ringing tone frequency and up to four ringing cadences. It
is applicable for VCX V7111 FXS Gateways. Only single ringing pattern can be defined, if not
a default ringing pattern applies. The ringing frequency can be configured in the range from
10 Hz through 200 Hz with a 5 Hz resolution. Each ringing cadence period can be defined as
single ringing burst. See the following examples.
3Com VCX V7111 VoIP SIP Gateways User Manual
97
Need help?
Do you have a question about the V7111 - VCX 4 Channels Analog FXO Media Gateway and is the answer not in the manual?
Questions and answers