Detailed self-test mode is invoked when initialization of the Gateway is completed and if the
configuration parameter EnableDiagnostics is set to 1 (this parameter can be configured
through the INI file). In this mode, the Gateway tests all the hardware components (such as
memory and DSP), outputs the status of the test results, and ends the test. To continue
operational running, reset the Gateway again but this time configure the EnableDiagnostics
parameter to 0.
RS-232 Terminal
The VCX V7111 status and error messages can be viewed using a terminal connected to the
RS-232 management port.
To connect VCX V7111 to a HyperTerminal using a standard RS-232 straight cable (not a
cross-over cable) with DB-9 connectors, connect the VCX V7111 RS-232 port (it is marked
RS232) to either COM1 or COM2 RS-232 communication port on the PC. The connector
pinout and gender are shown in
RS-232 Cable Wiring
Figure 58
2
3
5
DB-9 female for PC
To configure the HyperTerminal, follow these steps:
On a PC running a Windows operating system, open
1
Start>Programs>Accessories>Communications>HyperTerminal. The Connection
Description dialog opens.
Enter a name for the new connection in the Name field and click OK; the Connect To
2
dialog opens.
In the Connect To dialog, enter COM1 or COM2, depending on the physical connection
3
you performed when connecting the VCX V7111 to the PC with the RS-232 cable; the
COM1/2 Properties dialog opens.
In the COM1/2 Properties dialog, enter the following settings for the serial
4
communication port:
Baud Rate: 115,200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: Hardware
3Com VCX V7111 VoIP SIP Gateways User Manual
Figure
58.
2
RD
3
TD
5
GND
DB-9 male for VCX V7111
125