Memory Back-Up Circuit - Epson DLQ-3000 Service Manual

24-pin dot matrix printer
Hide thumbs Also See for DLQ-3000:
Table of Contents

Advertisement

DLQ-3000+

2.3.3 Memory Back-up Circuit

When the printer power is turned off, mainly the following data is backed up in the
EEPROM AT93C66 (IC23).
Paper length, TOF, TEAR OFF, left and right margins, line spacing, pitch
selection, character code, character fonts, high speed print, print direction,
customer code
Interface setting
Values used for controlling the mechanism (condition for all the sensors)
Adjusted values used for controlling the mechanism (i.e. Bi-D adjustment, PG
adjustment and PG
IPD ID for the boot strap program
The first operation date, accumulated print amount, accumulated power-on time
and timing for ribbon replacement
Data to be backed up is transferred by the gate array as serial data. At printer power off, the
gate array outputs the chip select signal ESC from port 126 and data to be backed-up is
sent to the EEPROM from port 124 (EDO) before the power supply voltage completely
drops. The data stored in the EEPROM is read by sending data to the EDI terminal in the
gate array when the printer is turned on. ECK is the clock signal for synchronization.
Figure 2-14.Memory Back-up Circuit Block Diagram
2-20
value)
Rev. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dlq-3000+

Table of Contents