3.2.6.4 PF Sensor Assembly Removal
Step 1) Remove the printer mechanism. (See Section 3.2.6.1.)
Step 2) Release the hooks attaching the PF sensor to the left frame. Then remove the
sensor.
Figure 3-15 Removal. PF Sensor Assembly Removal
3.2.6.5 PF Motor Assembly Removal
Step 1) Remove the printer mechanism. (See Section 3.2.6.1.)
Step 2) Disconnect the harness for the PF motor assembly from the right side of the printer
mechanism.
Step 3) Remove 1 screw (CBS, 3X6) securing the grounding plate to the bottom of the
printer mechanism. Then remove the grounding plate.
Step 4) Remove 2 screws (CP, P4, 3X6) securing the PF motor assembly to the right side
of the printer mechanism.
Step 5) Remove the PF tension shaft from the PF motor assembly, and remove the PF
motor assembly.
Perform "Belt tension adjustment". (Refer to Chapter 4 Adjustment.)
Rev. A
WORK POINT
Figure 3-16. PF Motor Assembly Removal
Disassembly and Assembly
3-15