HP Bc1500 - BladeSystem - Blade PC User Manual page 66

Bladesystem pc blade enclosure integrated administrator for cci v1.4
Hide thumbs Also See for Bc1500 - BladeSystem - Blade PC:
Table of Contents

Advertisement

Command Line Interface
Blade PC Bay Management Commands (continued)
GENERATE
NMI
<bay number>
POWEROFF
BAY
<bay number>
{[ , | - ] <bay
number>}
{FORCE}
POWERON
BAY
<bay number>
{[ , | - ] <bay
number>} {[PXE
| HDD |
RBSU]}
REBOOT BAY
<bay number>
{[ , | - ] <bay
number>}
{FORCE} {[PXE
| HDD |
RBSU]}
SET BAY BOOT
FIRST [HDD |
PXE] <bay
number> {[ , | -
] <bay
number>}
SET BAY BOOT
ONCE [HDD |
PXE | RBSU]
<bay number>
{[ , | - ] <bay
number>}
5-16
Generates an NMI on the specified blade.
The consequences of an NMI are
operating system specific.
Performs a graceful shutdown of the blade
PC in the specified bay.
If the FORCE argument is given, the blade
PC is immediately shut down. This means
the blade PC could lose data or become
unstable. If no blade PC is in the specified
bay, the user is told that the bay is empty.
Powers on the specified blade PC.
If no blade PC is in the specified bay, the
user is told that the bay is empty.
The optional boot arguments may require
a firmware update for the BIOS ROM of
certain HP blade PCs.
Adding an optional boot argument forces
the blade to abandon the regular boot
order and forces a boot using the specified
method.
Sends a request to the blade PC to perform
a graceful shutdown.
The blade PC is then powered on. If no
blade PC is in the specified bay, the user is
told that the bay is empty.
The optional boot arguments may require
a firmware update for the BIOS ROM of
certain HP blade PCs.
Adding an optional boot argument forces
the blade to abandon the regular boot
order and forces a boot using the specified
method.
Sets the IPL for each subsequent reboot.
This setting is only valid for present blades
and is cleared if a blade is removed.
This command may require a firmware
update for the BIOS ROM of certain HP
blade PCs.
Sets the boot device to be used on the next
boot of the bay(s) specified. This setting is
only valid on present blades and is cleared
if the blade is removed.
This command may require a firmware
update for the BIOS ROM of certain HP
blade PCs.
HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide
Only enclosure and group
administrators may execute
this command.
Only enclosure and group
administrators may execute
this command.
Only enclosure and group
administrators may execute
this command.
Only enclosure and group
administrators may execute
this command.
Only enclosure and group
administrators may execute
this command.
Only enclosure and group
administrators may execute
this command.

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Pc blade enclosure integrated administrator

Table of Contents