Command Line Interface
Enclosure Network Configuration Commands (continued)
Command
ENABLE
TELNET
ENABLE WEB
REMOVE
SNMP
TRAPRECEIVER
<IP address>
SET DNS
<primary
address>
{<secondary
address>}
SET GATEWAY
<IP address>
SET IPCONFIG
[DHCP
{DYNAMICDN
S} | STATIC <IP
address>
<netmask>]
SET SNMP
COMMUNITY
[READ |
WRITE]
<community
name>
5-10
Description
Enables Telnet access to the Integrated
Administrator.
Enables HTTP and HTTPS access to the
Integrated Administrator.
Removes an IP address from the list of
systems to receive SNMP traps
Sets the primary and secondary DNS
server addresses
These servers are only used if the system
is currently configured to use a static IP
address.
Sets the network default gateway
This gateway is only used if the system is
configured to use a static IP address.
Sets up the Integrated Administrator IP
configuration
The gateway and DNS addresses are
cleared. The optional DYNAMICDNS
argument enables Dynamic DNS.
Sets the community name for the read or
write SNMP community
The default names for the read and write
community are public and blank,
respectively. If a blank write community
name is given, SNMP set commands are
disabled until a non-empty community
name is given.
HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide
Restrictions
Only enclosure administrators
may execute this command.
Only enclosure administrators
may execute this command.
Only enclosure administrators
may execute this command.
The IP address must be in the
form ###.###.###.### where
### ranges from 0 to 255.
Only enclosure administrators
may execute this command.
The IP address must be in the
form ###.###.###.### where
### ranges from 0 to 255.
Only enclosure administrators
may execute this command.
The IP address must be in the
form ###.###.###.### where
### ranges from 0 to 255.
Only enclosure administrators
may execute this command.
The IP address must be in the
form ###.###.###.### where
### ranges from 0 to 255.
Only enclosure administrators
may modify another user's
contact information.
The write <community name>
must be 0-20 characters long,
and the read <community
name> must be 1-20 characters
long. Both can include
alphanumeric, dash, and
underscore characters.
The default read community
name is public. The default
write community name is blank.

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Pc blade enclosure integrated administrator

Table of Contents