2.19.2 Lamp Mode, Read
Description
Reads the actual Lamp mode of the projector
Command
Command [0]
Command [1]
Returned Data
Data[0]: unsigned byte
data byte value: 0 = Single mode ; 1= Dual mode
Example
Reads the actual Lamp mode of the projector, the awnser being \x00 = single mode.
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (acknowledge)
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
Receive (Answer)
Start
Projector address
Command[0]
Command[1]
Data [0]
Checksum
Stop
R59770077 RS 232 SERIAL COMMUNICATIONS FOR ICON H250/400 16/02/2007
\x21
\x0c
\xfe
\x01
\x21
\x0c
\x44
\xff
\xfe
\x01
\x00
\x06
\x07
\xff
\xfe
\x01
\x21
\x0c
\x00
\x2e
\xff
2. Basic commands
83