Chapter 54
Configuring Call Home
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 54-2
Event Triggers (continued)
Event
Alert Group
Inventory
Inventory and
CISCO_TAC
Test
Test and
CISCO_TAC
Port syslog Syslog-group-
port
RMON
RMON
Table 54-3
Table 54-3
Event Categories and Executed Commands
Event Category
System
Environmental
Line Card Hardware
Supervisor Hardware
Inventory
Test

Call Home Message Levels

Call Home messages (sent for syslog alert groups) have the syslog severity level mapped to the Call
Home message level (see the
This section discusses the severity levels for a Call Home message when using one or more switches in
the Cisco MDS 9000 Family. Call Home message levels are preassigned per event type.
Severity levels range from 0 to 9, with 9 having the highest urgency. Each syslog level has keywords and
a corresponding syslog level as listed in
Call Home does not change the syslog message level in the message text. The syslog message texts in
Note
the Call Home log appear as they are described in the
OL-16184-01, Cisco MDS SAN-OS Release 3.x
Event Name
COLD_BOOT
HARDWARE_INSERTION
HARDWARE_REMOVAL
TEST
SYSLOG_ALERT
RMON_ALERT
lists event categories and command outputs.
Description
Events generated by failure of a software system that is critical to unit
operation.
Events related to power, fan, and environment sensing elements such
as temperature alarms.
Events related to standard or intelligent line card hardware.
Events related to supervisor modules.
Inventory status is provided whenever a unit is cold booted, or when
FRUs are inserted or removed. This is considered a noncritical event,
and the information is used for status and entitlement.
User generated test message.
"Syslog-Based Alerts" section on page
Description
Switch is powered up and reset to a cold
boot sequence.
New piece of hardware inserted into the
chassis.
Hardware removed from the chassis.
User generated test.
Syslog messages corresponding to the
port facility.
RMON alert trigger messages.
Table
54-4.
Cisco MDS 9000 Family System Messages Guide.
Cisco MDS 9000 Family CLI Configuration Guide
Call Home Message Levels
Call Home
Message Level
2
2
2
2
2
2
Executed Commands
show tech-support
show system redundancy
status
show module
show environment
show tech-support
show tech-support
show version
show version
54-10).
54-23