Test Run Requirements; Tests For A Specified Module - HP Cisco MDS 9020 - Fabric Switch Configuration Manual

Cisco mds 9000 family cli configuration guide, release 3.x (ol-16184-01, april 2008)
Hide thumbs Also See for Cisco MDS 9020 - Fabric Switch:
Table of Contents

Advertisement

Chapter 59
Monitoring System Processes and Logs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
To configure failure action in a switch, follow these steps:
Command
Step 1
switch# config terminal
switch(config)#
Step 2
switch(config)# system health failure-action
System health global failure action is now enabled.
Step 3
switch(config)# no system health failure-action
System health global failure action now disabled.
Step 4
switch(config)# system health module 1
failure-action
System health failure action for module 1 is now
enabled.
Step 5
switch(config)# no system health module 1 loopback
failure-action
System health failure action for module 1 loopback
test is now disabled.

Test Run Requirements

Enabling a test does not guarantee that a test will run.
Tests on a given interface or module only run if you enable system health for all of the following items:
The test will not run if system health is disabled in any combination. If system health is disabled to run
Tip
tests, the test status shows up as disabled.
Tip
If the specific module or interface is enabled to run tests, but is not running the tests due to system health
being disabled, then tests show up as enabled (not running).

Tests for a Specified Module

The system health feature in the SAN-OS software performs tests in the following areas:
OL-16184-01, Cisco MDS SAN-OS Release 3.x
The entire switch.
The required module.
The required interface.
Active supervisor's in-band connectivity to the fabric.
Standby supervisor's arbiter availability.
Bootflash connectivity and accessibility on all modules.
EOBC connectivity and accessibility on all modules.
Data path integrity for each interface on all modules.
Management port's connectivity.
Caching Services Module (CSM) batteries (for temperature, age, full-charge capacity, (dis)charge
ability and backup capability) and cache disks (for connectivity, accessibility and raw disk I/O).
Online System Health Management
Purpose
Enters configuration mode.
Enables the switch to take failure action
(default).
Reverts the switch configuration to
prevent failure action being taken.
Enables switch to take failure action for
failures in module 1.
Prevents the switch from taking action on
failures determined by the loopback test
in module 1.
Cisco MDS 9000 Family CLI Configuration Guide
59-15

Advertisement

Table of Contents
loading