Connecting The Ink Tubes To The Ink Pipes; Securing The The Ink Tubes And Ink Pipes; Securing The Tube Guides On The Cr Side - Epson Stylus Pro 9000 - Print Engine Service Manual

Wide-format professional inkjet printer
Hide thumbs Also See for Stylus Pro 9000 - Print Engine:
Table of Contents

Advertisement

EPSON Stylus Pro 9000

CONNECTING THE INK TUBES TO THE INK PIPES

1. Make sure the ink tubes on the ink pipe side are uncovered for about
45 mm.
2. Make sure there is a screw and O-ring on the end of each ink tube. If some
are missing, use ones from the old ink tubes.
3. Insert the inner clear tube into the corresponding color ink pipe as far as it
will go. Repeat for all six tubes.
4. Secure the joint screws by hand temporally, and use the torque wrench
(1.75Å}0.25kgf/cm) to fasten the screws completely. The ink tube must be
inserted completely, and the O-ring must not be twisted.
Make sure the end of the tube guide that attaches to the ink
pipes has only FOUR joints.
CR cable
fixing plate
CR fixing plate C
(underneath)
Tube guide
Disassembly & Assembly
Tube guide
fixing plate
6mm

SECURING THE THE INK TUBES AND INK PIPES

1. Slide the UL tube adjuster (on the end of each tube) towards the joint
screw side.
2. Place the CR fixing plate over the ink tubes and carefully but firmly press
down until all three tubes are secure. Repeat for the other side.
3. Secure the tube guides and ink tubes with the CR cable fixing plates and
tube guide fixing plate, then insert and close two screw(3Å~20) to secure
the CR cable fixing plates. At this time, the tube guide sticks out about
6mm from the tube guide fixing plate.
4. Place the black tube fixing plate over the ink pipes (over the black pad),
and press down to make sure all the pipes are secured by the plate.
Secure the plate with a screw (3Å~16), and repear for the other side.

SECURING THE TUBE GUIDES ON THE CR SIDE

1. Place both tube guides on the cable connection plate, aligning the ends of
both tube guides with the far edges of the cable connection plate.
2. Put the right-side protective film on top of the cable connection plate and
tube guide. Make sure the protective film is not too loose or too tight.
3. Put the new tube guide fixing plate on top of the tube guides and protective
film, and secure all with three screws.
4. Make sure there is no gap between the protective film and the tube guide.
Tube guide
fixing plater
Protective
film
Align the
edge of the
tube guide
here.
96