EPSON Stylus Pro 9000
5. Loosen two screws securing the fixintg plate that holding the ink tubes and
a FFC inside the I/H assembly. And unhook two tabs and remove the hand
hold cover.
6. Remove the two screws (CP(W2) M3x6) securing the ink tube holder plate,
and disconnect the FFC from the connector on the I/H relay board attached
at the bottom of the I/H assembly as shown at right.
To remove two screws securing the ink tube holder plate,
you need a short-neck screwdriver.
Figure 4-48. Removing the fixing plate
Disassembly & Assembly
Push to release
the tabs
Figure 4-49. Removing the FFC
85