Reset; Save - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks mpx200 multifunction router user guide (5697-0306, january 2010)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

Reset

Restores the router configuration parameters to the factory default values. The reset factory
command deletes all LUN mappings, as well as all persistent data for targets, LUNs, initiators, VPG
settings, log files, iSCSI and management IP addresses, FC and Ethernet port statistics, and passwords.
This command also restores the factory default IP addresses. The reset mappings command clears
only the LUN mappings.
Authority
Syntax
Keywords
Example 1:
MPX200 <1>(admin) #> reset factory
Are you sure you want to restore to factory default settings (y/n): y
Please reboot the System for the settings to take effect
Example 2:
MPX200 <1>(admin) #> reset mappings
Are you sure you want to reset the mappings in the system (y/n): y
Please reboot the System for the settings to take effect.

Save

Saves logs and traces.
Authority
Syntax
Keywords
Admin session
factory
reset
mappings
Deletes all LUN mappings, as well as all persistent data for
targets, LUNs, initiators, VPG settings, log files, iSCSI and
factory
management IP addresses, FC and Ethernet port statistics,
and passwords.
map-
Clears only the LUN mappings
pings
Admin session
capture
logs
save
traces
The save capture command creates a debug file that
captures all debug dump data. When the command has
capture
finished executing, you must FTP the debug capture file from
the blade.
The save logs command creates a tar file that contains
the router's log data, storing the file in the router's /var/
logs
ftp directory. When the command has finished executing,
you must FTP the log's tar file from the blade.