HP StorageWorks 6100 - Enterprise Virtual Array User Manual page 76

Hp storageworks mpx200 multifunction router user guide (5697-0306, january 2010)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

2.
Add array_ctrl to device-type-config-list:
device-type-config-list="array_ctrl";
3.
Uncomment all target/LUN pair entries.
Example: HP storage array settings in /kernel/drv/sgen.conf
.
.
.
# devices on your system.
#
# sgen may be configured to bind to SCSI devices exporting a particular device
# type, using the device-type-config-list, which is a ',' delimited list of
# strings.
#
device-type-config-list="array_ctrl";
.
.
.
# After configuring the device-type-config-list and/or the inquiry-config-list,
# the administrator must uncomment those target/lun pairs at which there are
# devices for sgen to control.
# sgen will be hotplugged or added into the system later, it is recommended
# that all of the following lines be uncommented.
name="sgen" class="scsi" target=0 lun=0;
name="sgen" class="scsi" target=1 lun=0;
name="sgen" class="scsi" target=2 lun=0;
name="sgen" class="scsi" target=3 lun=0;
name="sgen" class="scsi" target=4 lun=0;
name="sgen" class="scsi" target=5 lun=0;
name="sgen" class="scsi" target=6 lun=0;
name="sgen" class="scsi" target=7 lun=0;
name="sgen" class="scsi" target=8 lun=0;
name="sgen" class="scsi" target=9 lun=0;
name="sgen" class="scsi" target=10 lun=0;
name="sgen" class="scsi" target=11 lun=0;
name="sgen" class="scsi" target=12 lun=0;
name="sgen" class="scsi" target=13 lun=0;
name="sgen" class="scsi" target=14 lun=0;
name="sgen" class="scsi" target=15 lun=0;
Creating an sgen driver alias
The HP storage array is a self-identifying SCSI device and must be bound to the sgen driver using
an alias.
76
MPX200 iSCSI configuration rules and guidelines
Please refer to sgen(7d) for details.
If it is expected that devices controlled by

Advertisement

Table of Contents
loading

Table of Contents