Dell PowerConnect 5548P System User's Manual page 190

Dell - powerconnect switch
Hide thumbs Also See for PowerConnect 5548P:
Table of Contents

Advertisement

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Link Local Interface — When the server supports an IPv6 Link Local
address, this specifies the Link Local interface. Select one of the
possible options:
VLAN — The VLAN on which the IPv6 interface is configured.
ISATAP — The IPv6 interface is configured on an ISATAP
tunnel.
SNTP Server — Enter the SNTP server's IP address.
Poll Interval — Enable/disable polling the selected SNTP server for
system time information, when enabled.
Encryption Key ID — Check to use an encryption key, and select one
of the encryption keys that was defined in the SNTP Authentication
pages.
Defining SNTP Servers Settings Using CLI Commands
The following table summarizes the CLI commands for setting fields
displayed in the SNTP Server pages.
Table 9-10. SNTP Server CLI Commands
CLI Command
sntp server {ipv4-
address|ipv6-address|ipv6-
address|hostname} [poll]
[key key-id]
no sntp server {ipv4-
address|ipv6-address|ipv6-
address|hostname}
sntp unicast client poll
no sntp unicast client poll
show sntp status
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 1 / 1 2 - F O R P R O O F O N LY
Contax\CxUGSystemConfig.fm
Description
Configures the device to use SNTP to
request and accept SNTP traffic from a
server.
Use the no form of this command to
remove a server from the list of SNTP
servers.
Enables polling for the SNTP predefined
Unicast clients.
Use the no form of this command to
disable the polling for the SNTP client.
Displays the SNTP server statuses.
Dell PowerConnect 55xx Systems User Guide
189

Advertisement

Table of Contents
loading

Table of Contents