HP 316095-B21 - StorageWorks Edge Switch 2/24 Installation Manual page 56

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 installation guide (aa-rtdwc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Installing and Configuring the Edge Switch 2/24
7. Configure the Port Settings parameters as follows:
8. At the > prompt, enter the user-level password (the default is password). The
Figure 10: HyperTerminal window
9. At the C> prompt, enter ipconfig. The HyperTerminal window displays
56
— Bits per second — 115200
— Data bits — 8
— Parity — None
— Stop bits — 1
— Flow control — Hardware
When the parameters are set, click OK. The HyperTerminal window displays.
password is case sensitive. The HyperTerminal window displays with a C>
prompt at the top of the window
with configuration information listed as follows:
— MAC Address
— IP Address (default is 10.1.1.10, factory preset is 10.1.1.10)
— Subnet Mask (default is 255.0.0.0).
— Gateway Address (default is 0.0.0.0)
Only the IP Address, Subnet Mask, and Gateway Address fields are
configurable.
(Figure
10).
Edge Switch 2/24 Installation Guide