Task 7: Configure Management Server Password And Network Addresses - McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Task 7: Configure Management Server Password and Network
Addresses
10. After successful POST completion, the LCD panel displays a
Welcome!! message and all front panel LEDs extinguish.
11. If a POST error or other malfunction occurs, go to
MAP
on page 3-6 to isolate the problem.
12. Press the left edge (PUSH label) of the LCD panel to disengage
the panel and expose the CD-RW drive.
13. Insert a blank rewritable CD into the CD-RW drive and close the
LCD panel.
Verify the type of LAN installation with the customer's network
administrator. If the management server or Fabricenter equipment
cabinet is installed on a dedicated LAN, network information does
not require change. Change the default password for the server's
LCD panel
(if required by the customer), then go to
Server Information
on page 2-30.
If the management server or Fabricenter equipment cabinet is
installed on a public LAN segment, the default password for the
server's LCD panel and the following transmission control protocol
internet protocol (TCP/IP) network information must be changed to
conform to the customer's LAN addressing scheme:
IP address.
Subnet mask.
NOTE: At some customer installations, TCP/IP addresses for the
management server may be allocated automatically using dynamic host
configuration protocol (DHCP).

Task 7: Configure Management Server Password and Network Addresses

Installation Tasks
MAP 0000: Start
Task 8: Configure Management