Event Code: 312
Message:
Third cooling fan propeller has recovered
Severity:
Informational
Explanation:
Another fan started spinning. It either spontaneously recovered or its FRU was replaced. Three fans are now
operational.
Action:
No action required.
Event Data:
Byte 0 = Recovered fan number (1-6).
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 313
Message:
Fourth cooling fan propeller has recovered
Severity:
Informational
Explanation:
Another fan started spinning. It either spontaneously recovered or its FRU was replaced. Four fans are now
operational.
Action:
No action required.
Event Data:
Byte 0 = Recovered fan number (1-6).
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator