McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 283

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event
Explanation
Code
806
Critically hot temperature warning (SBAR assembly
thermal sensor).
807
SBAR assembly shutdown due to thermal violation.
810
High temperature warning (CTP card thermal sensor).
811
Critically hot temperature warning (CTP card thermal
sensor).
812
CTP card shutdown due to thermal violation.
850
System shutdown due to CTP card thermal violations.
3
Is fault isolation being performed at the switch or EFC Server?
YES
NO
Fault isolation is being performed through the SANpilot
interface or EFC Server (or customer-supplied server). Go to
step
6.
4
Does a blinking red and yellow diamond (failed FRU indicator) appear
to overlay a cooling fan graphic at the Hardware View?
NO
YES
Go to
step
8.
5
Does inspection of a fan indicate a failure? Indicators include:
The amber LED at the upper left corner of a fan illuminates.
The fan is not rotating.
NO
YES
Go to
step
8.
The switch appears operational.
MAP 0500: Fan and CTP Card Failure Analysis
Diagnostics
Action
Go to
step
8.
Go to
step
8.
Go to
step
8.
Go to
step
8.
Go to
step
8.
Go to
step
8.
3-69