McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 307

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event
Explanation
Code
011
Login server database invalid.
021
Name server database invalid.
051
Management server database invalid.
052
Management server internal error.
061
Fabric controller database invalid.
062
Maximum interswitch hop count exceeded.
063
Remote switch has too many ISLs.
070
E_Port is segmented.
071
Switch is isolated.
072
E_Port connected to an unsupported switch.
140
Congestion detected on an ISL.
142
Low BB_Credit detected on an ISL.
150
Zone merge failure.
3
Is fault isolation being performed at the EFC Server?
YES
NO
Fault isolation is being performed through the SANpilot
interface. Go to
4
Does a yellow triangle (attention indicator) appear to overlay the port
graphic at the Hardware View?
YES
NO
The problem is transient and the switch-to-fabric device
connection appears operational.
5
Inspect the port state and LED status for the port.
MAP 0700: Fabric, ISL, and Segmented Port Problem Determination
step
18.
Diagnostics
Action
Go to
step
7.
Go to
step
7.
Go to
step
7.
Go to
step
7.
Go to
step
7.
Go to
step
8.
Go to
step
10.
Go to
step
10.
Go to
step
11.
3-93
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 3032Sphereon 3232