Event Code: 411
Message:
Firmware fault occurred
Severity:
Major
Explanation:
The firmware executing on the indicated CTP card encountered an unexpected operating condition and dumped
its current operating state to FLASH memory for retrieval and analysis.
All Fibre Channel connections to the switch are reset after the fault and IPL. Attached devices must re-login to the
switch to resume operations.
The dump file is automatically transferred from the switch to the EFC Server over the Ethernet LAN connection,
where it is stored for later retrieval during the data collection operation.
Action:
Perform the data collection procedure for this switch using the EFC Manager, and return the CD to McDATA for
analysis.
Event Data:
Bytes 0-3: Fault identifier, least significant byte first (e.g., event data 33 22 11 00).
Bytes 4 - 7: Fault identifier specific data.
Bytes 8 - 11: Fault identifier specific data.
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
CTP Card Events (400 through 499)