McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 457

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Code: 081
Message:
Port has been set to Invalid Attachment state.
Severity:
Informational
Explanation:
The port has recognized an incompatibility with the device connected to the other end of the link, preventing the
two devices from joining. Ports that are isolated will not carry Class 2 or Class 3 traffic, and will reject Class F
traffic..
Action:
Action depend on the event data.
Event Data:
Byte 0 = Port number.
Bytes 1 - 3 = reserved.
Byte 4 = Reason Code
01 = Unknown reason.
02 = Non E_Port mode..
03 = Process ELP reject with Unable-to-Process reason code.
04 = Procxess ELP reject with invalid revision level.
05 = Loopback indication.
06 = Non F_Port mode.
07 = When in legacy mode detect connection over E_Port of a non-McDATA switch based on the
08 = Not used.
09 = Not used.
0A = Unauthorized port binding WWN.
0B = G_Port ELP timeout.
0C = ESA security mismatch.
0D = Fabric binding mismatch.
0E = Authorization failure reject.
0F = Unauthorized switch binding.
10 = Authentication Failure. ISL Authentication check failed.
11 = Fabric Mode Mismatch.
12 = CNT WAN Extension Mode Mismatch.
Bytes 8-16 = WWN of device attached.
Distribution:
Switch
Nonvolatile
System
Event Log
WWN.
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
System Events (000 through 199)
Event Code Tables
Host
Sense Info
Link Incident
B
B-13

Hide quick links: