Event Code: 051
Message:
Management Server database found to be invalid
Severity:
Minor
Explanation:
Following an IML, CTP hot-plug, CTP failover, or LIC load, a Management Server database failed its validation.
All Management Services databases are initialized to an empty state resulting in an implicit logout of all attached
devices logged in with the Management Server.
Action:
Perform the data collection procedure for the switch using the EFC Manager, and return the CD to McDATA for
analysis.
Event Data:
No supplementary data included with this event.