Does the Operational State field display a Beaconing message and
the Beaconing field display an On message?
YES
NO
Go to
step
47.
46
Port beaconing is enabled.
a. Consult the customer and next level of support to determine the
reason port beaconing is enabled.
b. Disable port beaconing:
1. At the View panel, select Operations at the left side of the
panel. The Operations panel opens with the Port Beaconing
page displayed.
2. Click the Beaconing State check box for the port. The check
mark disappears from the box and port beaconing is
disabled.
3. Return to the View panel (Port Properties tab).
Continue.
47
At the View panel, does the Operational State field display a
Segmented message?
NO
YES
Port segmentation is indicated. Go to
codes. If no event codes are found, go to
ISL, and Segmented Port Problem Determination
page 3-92.
48
At the View panel, does the Operational State field display a message
indicating a link incident or port problem?
NO
YES
A port problem is indicated. Go to
codes. If no event codes are found, go to
Failure and Link Incident Analysis
49
Repeat
step 45
through
step 52
step 52
on page 3-72.
step 48
for each remaining port.
MAP 0000: Start MAP
Diagnostics
to obtain event
MAP 0700: Fabric,
on
to obtain event
MAP 0600: Port
3-25
3