Installation Tasks
2
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
2-90
• Prohibit or allow connections for an entire row (row 0C is
prohibited in the Configure Addresses - Active dialog box
example).
• Prohibit or allow connections for all switch ports.
• Block or unblock all switch ports.
• Clear connectivity restrictions for all switch ports.
3. At the CUP Name field, type a control unit port description of 24
or fewer alphanumeric characters (optional). The CUP is an
internal switch port that communicates with channels to report
errors and link initialization.
4. Perform one of the following to activate the configuration
(without saving it), or save the configuration for later activation:
— Activate the Configuration - click Activate to activate the
configuration changes (without saving) and close the
Configure Addresses - Active dialog box.
— Save the Configuration - click Save As. The Save Address
Configuration As dialog box displays.
Figure 2-73

Save Address Configuration As Dialog Box

• At the Name field, type a configuration name of 8 or fewer
alphanumeric characters.
• At the Description field, type a configuration description of
24 or fewer alphanumeric characters.
• Click OK to save the configuration in the address
configuration library and close the Save Address
Configuration As dialog box.
• At the Configure Addresses - Active dialog box, click Activate
to activate the configuration and close the dialog box, or
click Close to close the dialog box.