Event Code Tables
B
Event Code: 605
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
B-72
SBAR module revision not supported
Minor
The specified SBAR module is not recognized by the existing firmware. The SBAR module will appear uninstalled
to system software.
Ensure that the switch model supports the operating firmware. If the firmware supports the model, perform the
data collection procedure for the switch using the EFC Manager. If the problem persists following a system
power-on reset, replace the switch and return the switch and the CD to McDATA for analysis and repair.
Byte 0 = Slot position
Bytes 4-7 = Elapsed millisecond tick counter
Bytes 8-9: = Detected Module identifier
Switch
Nonvolatile
System
System
Error
Event Log
Indicator
EFC Server
Event Log
E-Mail
Host
Call-Home
Sense Info