Diagnostics
3
MAP 0700: Fabric, ISL, and Segmented Port Problem
Determination
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
3-92
Did the link incident recur?
YES
NO
The attached device, Fibre Channel link, and switch appear
operational. Exit MAP.
Contact the next level of support. Exit MAP.
40
The switch port reporting the problem is causing the recurrent link
incident. The recurring link incident indicates port degradation and a
possible pending failure. Go to
This MAP describes isolation of fabric logout, interswitch link (ISL),
and port segmentation problems. Failure indicators include:
An event code recorded at the Sphereon 3032/3232 Event Log or
the SANpilot event log.
A segmentation reason associated with the port at the SANpilot
interface.
A yellow triangle (attention indicator) appears at the Product View
or Hardware View.
A link incident message recorded in the Link Incident Log or Port
Properties dialog box.
1
Was an event code 011, 021, 051, 052, 061, 062, 063, 070, 071, 072,
081, 140, 142, or 150 observed at the Sphereon 3032/3232 Event
Log (EFC Server) or at the SANpilot event log?
YES
NO
Go to
step
3.
2
The following table lists event codes, brief explanations of the codes,
and associated steps that describe fault isolation procedures.
step
6.