The Fibre Channel link and switch appear operational.
Exit MAP.
37
Clean fiber-optic connectors on the jumper cable.
a. Notify the customer the port will be blocked. Ensure the
customer's system administrator quiesces Fibre Channel frame
traffic through the port and sets the attached device offline.
b. Block the port. Refer to
c. Disconnect both ends of the fiber-optic cable.
d. Clean the fiber-optic connectors. Refer to
Components
on page 4-48.
e. Reconnect the fiber-optic cable.
f. Unblock the port. Refer to
g. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
NO
The Fibre Channel link and switch appear operational.
Exit MAP.
38
Disconnect the fiber-optic jumper cable from the switch port and
connect the cable to a spare port.
Is a link incident reported at the new port?
YES
NO
Go to
step
40.
39
The attached device is causing the recurrent link incident. Notify the
customer of the problem and have the system administrator:
a. Inspect and verify operation of the attached device.
b. Repair the attached device if a failure is indicated.
c. Monitor port operation for approximately five minutes.
MAP 0600: Port Failure and Link Incident Analysis
Block or Unblock a Port
Clean Fiber-Optic
Block or Unblock a Port
Diagnostics
on page 4-45.
on page 4-45.