Fujitsu BX630 - PRIMERGY - S2 Dual Operating Manual page 81

Scalable server blade
Hide thumbs Also See for BX630 - PRIMERGY - S2 Dual:
Table of Contents

Advertisement

Hot-plug components
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
If you want to remove an HDD module during operation, proceed as follows:
Ê If you want to remove a HDD module that is not defective, the drive must be
first set to offline via the software (RAID controller configuration software).
Ê Unlock the HDD module as described in section
module" on page
Ê Pull the HDD module out a few centimeters.
Ê Wait for at least 60 seconds.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê Pull the HDD module out completely.
Ê Install the new HDD module, as described in
module" on page 79
V
CAUTION!
If you have removed an HDD module and do not install a new one in
its place, put the dummy module back in its place for cooling, to
comply with EMC regulations (regulations regarding electromagnetic
compatibility), and for protection against fire. Ensure that the dummy
module engages correctly in the slot.
BX630 S2
Installing/removing a hard disk module
79.
and
"Installing a hard disk module" on page
Operating Manual
"Unlocking the hard disk
"Unlocking the hard disk
80.
81

Advertisement

Table of Contents
loading

Table of Contents