Fujitsu BX630 - PRIMERGY - S2 Dual Operating Manual page 80

Scalable server blade
Hide thumbs Also See for BX630 - PRIMERGY - S2 Dual:
Table of Contents

Advertisement

Installing/removing a hard disk module
Installing a hard disk module
Figure 26: Installing a hard disk module
Ê Carefully push the hard disk module into the empty bay as far as it will go.
Ê Swivel the handle fully round in the direction of the arrow until the locking
mechanism engages.
Removing the hard disk module
V
CAUTION!
Only remove a HDD module during operation if the drive is not
currently being accessed. Observe the control LEDs for the corre-
sponding HDD modules (see
page
32).
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure whether the hard disk
drive is operated by a RAID controller and belongs to a disk array
which is operating at RAID level 1.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
80
"Control and Connection Panel" on
Operating Manual
Hot-plug components
BX630 S2

Advertisement

Table of Contents
loading

Table of Contents