2.2 WIRING DESCRIPTION

The wiring diagram below shows a typical wiring scheme for the telephone entry system.
Terminal 3 is a case ground and not a low voltage common. Using terminal 3 as a low
voltage common will cause noise on the phone line.
Switch input 1 (terminals 4 and 8) is pre-wired to the postal switch and pre-programmed to
activate relay 1 when the input is closed.
Switch input 2 can be programmed to activate relay 2 or dial a preprogrammed phone
number when the input is closed.
N o r m a l l y O p e n
Switch 2 Input
Central Office
P h o n e L i n e
1
2
3
4
5
E a r t h G r o u n d
Only
N o r m a l l y O p e n
Switch 1 Input
24
6
7
8
9
1 0
1 1
1 2
+
12 Volt
Battery
1 3
1 4
1 6 V A C , 2 0 V A
T r a n s f o r m e r