Error-, Warning- And Info-Messages - DURKOPP ADLER DAC BASIC - V 12-2010 Manual

Sewing machine drive
Hide thumbs Also See for DAC BASIC - V 12-2010:
Table of Contents

Advertisement

Available languages

Available languages

DAC basic/classic
14

Error-, warning- and info-messages

The control DAC
or DAC
basic
described.
Grad
Kürzel Beschreibung
Error
Err
Error
Switch off the control and eliminate the problem .
Warning
Wrn
Eliminate the state that caused to the warning. The control will normally worked.
Information Inf
Information push the OK-button
Further working should be possible. It could be that only only emergency run features are
possible.
Grad
Code
Fehler- bzw. Info- Beschreibung Abhilfe
Error
1000
Sewing motor encoder plug (Sub-D,
9 pin) not connected.
Error
1001
Sewing motor error
Sewing motor plug (AMP) is not
connected.
Error
1002
Sewing motor insulation error
Error
1004
Sewing motor turning in the wrong
direction
Error
1005
sewing motor blocked
Error
1006
maximum speed exceeded
Error
1007
Errors in the reference movement
Error
1052
Excess sewing motor current,
internal current increase >25A
Error
1055
Sewing motor overload
Information 1203
Position not reached (for thread
cutting, turning round etc. )
Error
3100
AC RDY timeout , intermediate
circuit voltage has not reached the
defined threshold in the given time.
Error
3101
High voltage error, mains voltage
>290V for some time
Error
3102
Low voltage failure (2nd threshold)
(mains voltage < 150V AC)
has got three groups of messages. In the following table this three groups are
classic
Error-, warning- and info-messages
- Insert the encoder lead into the control unit. Use the
right interface.
- Check the connection and if necessary plug in.
- Test sewing motor phases (R= 2.8 Ohm, high
resistance compared with PE)
- Replace sewing motor
- Replace control unit
- Check motor phase and PE for low-resistance
connection
- Replace sewing motor
- Replace encoder
- Check that the motor plug is in the right place and
change if necessary
- Check wiring in the machine distributor and change if
necessary
- Test motor phases and check for value
-Eliminate sluggish movement in the sewing machine
- Change the Encoder
- Reset the control unit
- Check the machine sub class ( t 51 04)
- Change the encoder
- Eliminate sluggish movement in the sewing machine
- Replace control unit
- Eliminate sluggish movement in the sewing machine
- Check controller settings and if necessary change,
mechanical changes to the machines, e.g. thread
cutter setting, belt tension etc.)
- Check the t
hread lever up position (Position 2)
- Check mains voltage
- If mains voltage OK, replace control unit
- Check mains voltage, if rated voltage exceeded
permanently - stabilise or use generator
- Check mains voltage
- Stabilise mains voltage
- Use generator
62
© 2010 Dürkopp Adler AG

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dac basicDac classic

Table of Contents