12.11.2
Setting other positions
The lower or upper position of the needle can be set directly using parameter t 08 12 or t 08 13 or by using
parameter t 08 11 in the same way as already described in 4.4.1.
The angle settings always relate to the set reference position.
12.12
Holding force when idle
L
C
P
Min
t
08 6
0
t
08 7
0,1
t
08 8
0
t
08 9
0
This function prevents unwanted wandering of the needle when the machine has stopped.
The effect can be checked by turning the hand wheel.
• Holding force takes effect when idle
- for a stop in the seam
- after the end of the seam
• The effect can be set
• The higher the value set the stronger the holding force
12.13
Setting parameters for backtack and seams
12.13.1
Stitching programming
L
C
P
Min
t
07 00 0
t
07 01 0
© 2010 Dürkopp Adler AG
Max
Unit
Description
2
-
Motor brake when stopped normally
0 = no brake;
1 = Brake for duration of d0815;
2 = Brake when stopped permanently active
6,00
A
Holding current when machine idle
255
-
Responsiveness to changes in the position
999
ms
Motor brake time period
Max
Unit
Description
2
-
Treatment position-2 in seam ways.
0 = Demolition of the seam. The next seam way is sewn; The seam is
1 = Demolition of the seam with thread performances (even if inactive).
2 = Demolition of the seam with thread performances (even if inactive).
1
-
Automatic system business.
0 = off;
1 = on
broken off with thread trimmer at the last seam of the program.
The next seam process is a free seam.
Seam program is stopped.
57