13

Hardware test

L
C
P
Min
t
51 12
-
By selecting parameter t 51 12 anc confirming by pressing OK, the following tests can be selected with buttons
A+ and A-. Confirm test selection with OK.
Display of various analog inputs, select with buttons A+ and A-
1. Analog
Interim circuit voltage
Control voltage
Output current total of I/O's
Analog pedal
Reduced speed(X1.4)
Analog input(X1.1 Only DAC classic )
Inputs' test (sensors)
2. Inputs
The function of all input components are checked automatically with this test. If the status of an input is changed,
this input and the status are automatically displayed on the screen.
Caution, danger of injury!
Only carry out an input test when the machine is running with the greatest care.
Outputs' test (actuators)
3. Output
The available outputs are selected with buttons A+ and A-. The output can be set with button D+ and reset with
button D-.
Caution! Risk of breaking!
Switching output components may lead to collisions with other machine components and
damage to the sewing machine.
Before switching on each output component ensure that it cannot collide with other
components.
© 2010 Dürkopp Adler AG
Max
Unit
Description
-
-
Hardware test
Nre
Ian
Um
: 230,0 [V]
U24
: 24,0 [V]
Imo
: 3,0
[A]
Pan
: 1024 <=> 3,3V
: 1024 <=> 3,3V
: 1024 <=> 3,3V