Grad
Code
Fehler- bzw. Info- Beschreibung Abhilfe
Information 3103
Low voltage warning (1st threshold)
(mains voltage < 180V AC)
Warning
3104
Pedal position is not at position 0
Error
3105
Short circuit U24V
Error
3106
Overload U24V (I²T)
Error
3107
Pedal not connected
Warning
3109
Maintaining safety
Information 3150
Maintenance required (info)
Warning
3151
Maintenance required (continue only
when parameters reset
t 51 14, see machine's operating
instructions)
Information 3215
Bobbin thread ounter (info value 0
reached)
Information 3216
Bobbin thread monitor left
Information 3217
Bobbin thread monitor right
Information 3218
Bobbin thread monitor left and right - Change left and right bobbin
Error
6353
Internal EEprom communication
error
Error
6351
External EEprom communication
error
Information 6360
No valid data on external EEprom
Information 6361
No external Eeprom connected
Information 6362
No valid data on internal EEprom
Information 6363
No valid data on internal or external
EEprom
(only emergency run features)
Information 6364
No valid data on internal EEprom
and external EEprom not connected
(only emergency run features)
Information 6365
Internal EEprom faulty
Information 6366
Internal EEprom faulty and external
data invalid
(only emergency run features)
Information 6367
Internal EEprom faulty and external
not connected
© 2010 Dürkopp Adler AG
Error-, warning- and info-messages
- Check mains voltage
- Stabilise mains voltage
- Use generator
When switching on the control unit, take foot off pedal
- 37 pin Take plug out, if error 3105 continues, replace
control unit
- Test inputs/ outputs for 24V short circuit
- one or more of the magnets faulty
- connect analogue pedal
- Check the tipping sensor on the machine
- For information on lubricating the machine see the
machine's service instructions
- carry out service urgently, see machine's service
instructions
- Change reel, set counter value - press counter reset
button
- Change left bobbin
- Change right bobbin
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Switch off control unit, wait until the LEDs go out and
check the connection of the mach-ID. Turn the control
on.
- Update software. The internal data structures are not
compatible with the external data memory
- Plug in mach ID
- Check connection mach-ID
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Update software. The internal data structures are not
compatible with the external data memory
- Check connection mach-ID
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Update software. The software version is not
compatible with the internal data memory
- Check connection mach-ID
- Switch off control unit, wait until the LEDs go out and
turn on again.
- Update software. The internal data structures are not
compatible with the external data memory
- Replace control unit
- Replace control unit
- Replace control unit