Setting The Basic Functions; Motor Rotation Direction; Selecting The Machine Model - DURKOPP ADLER DAC BASIC - V 12-2010 Manual

Sewing machine drive
Hide thumbs Also See for DAC BASIC - V 12-2010:
Table of Contents

Advertisement

Available languages

Available languages

DAC basic/classic
12

Setting the basic functions

All settings for operating the control unit can be made on the OP1000 control panel.
12.1

Motor rotation direction

L
C
P
Min
t
08 05 0
12.2

Selecting the machine model

The different types of machine are characterised by specific features. These parameters are prepared and already
saved at the factory in the MACH ID memory . This data memory is fitted to the upper part and is connected to the
control unit by a cable.
Mach - ID is available and is connected to the control unit:
Depending on the content of the Mach ID, special function processes for the type of machine and the different
preset values are enabled.
Mach ID is not available:
L
C
P
Min
t
51 10 0
The preset values for the machine classes must be loaded via the DA dongle.
If the machine parameters are not loaded, there can be no clear allocation to a machine class and so only
emergency run features will be enabled.
Max
Unit
Description
1
-
Motor rotation direction
0 = left;
1 = right
CAUTION
If the assembly of the motor is changed, e.g. rotated or with a speed reducer, you
must ensure that the value set with parameter t 08 05 for the direction of rotation has
been correctly allocated.
Max
Unit
Description
4
-
Loading parameters
0 = Nothing;
1 = Sewing data from DA dongle;
2 = Sewing data from the back up area;
3 = Sewing sections from DA dongle;
4 = Master Reset
46
Setting the basic functions
© 2010 Dürkopp Adler AG