Monitoring The Redundancy Status Of Srp Modules; Table 9: Show Redundancy Line-Card Output Fields - Juniper SERVICE AVAILABILITY - CONFIGURATION GUIDE V 11.1.X Configuration Manual

Software for e series broadband services routers service availability configuration guide
Table of Contents

Advertisement

JUNOSe 11.1.x Service Availability Configuration Guide
To display the redundancy status of the line modules.
Action
host1#show redundancy line-card
automatic reverting is off
slot
----
slots
------
8 - 13
Table 9 on page 52 lists the show redundancy line-card command output fields.
Meaning

Table 9: show redundancy line-card Output Fields

Related Topics

Monitoring the Redundancy Status of SRP Modules

Display redundancy information specific to SRP modules.
Purpose
52

Monitoring the Redundancy Status of SRP Modules

hardware
lockout
role
config
--------
---------
3
---
---
8
spare
---
12
primary
protected
midplane
midplane
type
rev
--------
--------
6
0
Field Name
automatic reverting
slots
hardware role
lockout config
backed up by slot
sparing for slot
revert at
midplane type
midplane rev
show redundancy line-card
backed
up
sparing
by
for
revert
slot
slot
at
------
-------
------
---
---
---
---
---
---
---
---
---
Field Description
State of automatic reverting (on or off).
Slots in which the line modules reside.
Function of the line module: primary or spare.
Status of redundancy on this line module:
protected Line module redundancy is enabled
locked out Line module redundancy is disabled
Slot that contains the line module that is a spare for
this primary line module.
Slot that contains the primary line module for which
this line module is a spare.
Time at which you want line module to revert.
Identifier for the type of midplane.
Hardware revision number of the redundancy
midplane.