load-interval
mru
mtu
Copyright © 2010, Juniper Networks, Inc.
Use to enable data stream inversion for the interface.
Enable data stream inversion only if it is turned on at the other end of the line.
Example
host1(config-if)#invert data
Use the no version to disable data inversion.
See invert data.
Use to set the time interval at which the router calculates bit and packet rate counters.
You can choose a multiple of 30 seconds, in the range 30–300 seconds.
Example
host1(config-if)#load-interval 90
Use the no version to restore the default value, 300 seconds.
See load-interval.
Use to configure the MRU size for the interface.
Specify a value in the range 4–9996 bytes.
You should coordinate this value with the network administrator on the other end of
the line.
If you configure a different MRU value in higher-level protocols, such as IP, the router
uses the lower value. This can produce unexpected behavior in your network.
Example
host1(config-if)#mru 1600
Use the no version to restore the default, 1600 bytes.
See mru.
Use to configure the MTU size for the interface.
Specify a value in the range 4–9996 bytes.
You should coordinate this value with the network administrator on the other end of
the line.
If you configure a different MTU value in higher-level protocols, such as IP, the router
uses the lower value. This can produce unexpected behavior in your network.
Example
host1(config-if)#mtu 1600