162
C-bit coding violations—Number of C-bit coding violations encountered by a T3 in
the current interval
Unavailable seconds—Number of unavailable seconds encountered by a T3 in the
current interval
Invalid seconds—Number of seconds when statistics were not collected
Field descriptions for a T1 channel
DS1—Identifier of T1 channel
Number of valid intervals—Number of 15-minute intervals since the line module was
last powered on or reset
Time elapse in current interval—Number of seconds that have passed in the 15-minute
(900-second) interval
Far End FDL Carrier bit—Status of FDL configuration on remote device connected to
T1 channel
set—FDL is configured for carrier mode
not set—FDL is not configured for carrier mode
Far End Equipment Identification Code—eic string sent by remote device for FDL
Far End Line Identification Code—lic string sent by remote device for FDL
Far End Frame Identification Code—fic string sent by remote device for FDL
Far End Unit Identification Code—unit string sent by remote device for FDL
Far End Facility Identification Code—pfi string sent by remote device for FDL
Far End Generator Number—generator string sent by remote device for FDL
Far End Port Number—port string sent by remote device for FDL
Errored seconds—Number of errored seconds encountered by a T1 in the current
interval
Severely errored seconds—Number of severely errored seconds encountered by a
T1 in the current interval
Severely errored frame seconds—Number of severely errored framing seconds
encountered by a T1 in the current interval
Unavailable seconds—Number of unavailable seconds encountered by a T1 in the
current interval
Clock slip seconds—Number of clock slips encountered by a T1 in the current interval
Path code violations—Number of coding violations encountered by a T1 in the current
interval
Copyright © 2010, Juniper Networks, Inc.