Juniper JUNOSE SOFTWARE FOR E SERIES 11.3.X - PHYSICAL LAYER CONFIGURATION GUIDE 2010-09-24 Configuration Manual page 171

Software for e series broadband services routers physical layer configuration guide
Table of Contents

Advertisement

baseline line section interface sonet
show controllers sonet configuration
Copyright © 2010, Juniper Networks, Inc.
Use the total [ delta ] keywords with the show controllers sonet path command to
view the baseline statistics.
Example
host1#baseline path interface sonet 2/0:1
There is no no version.
See baseline path interface sonet.
Use to set a statistics baseline for the SONET/SDH section layer.
The router implements the baseline by reading and storing the MIB statistics at the
time the baseline is set and then subtracting this baseline whenever baseline-relative
statistics are retrieved.
Use the total [ delta ] keywords with the show controllers sonet section command
to view the baseline statistics.
Example
host1#baseline section interface sonet 2/0
There is no no version.
See baseline section interface sonet.
Use to display the configuration for channelized SONET and SDH interfaces.
Specify an interface in slot/port format.
To view information for a controller and all layers above that controller, specify a
controller. For example, to view all controllers on interface 3/0, use show controllers
sonet 3/0 configuration. To view information for path 1 only, use show controllers
sonet 3/0:1 configuration.
Field descriptions
Interface specifier in slot/port format
channelized—Number of channels and speed for the interface
ifAdminStatus—Configured status of the interface: up or down
description—Configured description of the controller
snmp trap link-status—State of SNMP link status processing for the section and line
layers of the interface: enabled or disabled
alarms used for operational status calculation—Types of defects that the router
uses to determine the operational status of the interface at the section and line
layers
defect trigger soaking delay—Time that the router waits to set an alarm when the
router records a defect at the section or line layer
Chapter 4: Configuring Channelized OCx/STMx Interfaces
149