JunosE 11.3.x Physical Layer Configuration Guide

Configuring T1 Channels

controller t3
t1 clock source
14
host1(config-controll)#snmp trap link-status
Use the no version to disable SNMP link status processing.
See snmp trap ip link-status.
To configure T1 channels and subchannels:
From Global Configuration mode, specify the T3 controller in slot 0, port 1.
1.
host1(config)#controller t3 0/1
Assign a range of timeslots to a channel and subchannel.
2.
For example, assign the following range of timeslots: 1, 3–8, and 10 to channel 2,
subchannel 1. Timeslots 2, 9, and 11–24 are available for other subchannels.
host1(config-controll)#t1 2/1 timeslots 1,3-8,10

Optional Tasks

The T1 channel configuration commands enable you to specify options for a single channel,
multiple individual channels, ranges of channels, or any combination of the three types
of specifications. For example:
host1(config-controll)#t1 2,4,6-15,20-25 clock source line
The following configuration tasks are optional when you configure T1 channels:
Disable T1 channels.
Change the clock source.
Assign a text description or an alias to the interface.
Change the framing format.
Enable or disable SNMP link status processing.
Configure FDL messages.
Use to specify a T3 controller in slot/port format.
slot—Number of the slot in which the line module resides in the chassis
port—Number of the port on the I/O module
Example
host1(config)#controller t3 0/1
There is no no version.
See controller t3.
Copyright © 2010, Juniper Networks, Inc.