Advertisement

show controllers sonet ds1|e1
Copyright © 2010, Juniper Networks, Inc.
Loopback State: none
Mode: sonet
Timing source: internal module
Current section alarms: none
Current line alarms
: none
Channel configuration:
channel = 1, path = oc1, hierarchy = 1/1/1/1, current path alarms: none
ifAdminStatus: up
snmp trap link-status: disabled
alarms used for operational status calculation: LOP AIS
defect trigger soaking delay: 2500 milliseconds
c2 byte override 20
Operational Status: up
time since last status change: 00:05:37
Ds3 1, unchannelized
ifOperStatus =
ifOperUp
snmp trap link-status = disabled
Framing is C-BIT, Line Code is B3ZS, Clock Source is Internal - Module
See show controllers sonet.
Use to display E1 or T1 (DS1) statistics for the different layers in channelized SONET
and SDH interfaces. Figure 8 on page 109 shows the layers in the interface.
For definitions of the MIB statistics, see RFC 2495—Definitions of Managed Objects
for the DS1, E1, DS2 and E2 Interface Types (January 1999).
Specify an interface in slot/port format.
To view information for a specific controller in a layer, enter the specifier for the
controller and the type for the controller. For example, to view the E1 controller 1/1/1
on path 1 on the interface 4/0, enter show controllers sonet 4/0:1/1/1/1 e1.
To view information for all controllers above a particular layer, enter the specifier for
the layer and the type for the controller. For example, to view all E1 controllers on the
interface 4/0 path 1, enter show controllers sonet 4/0:1 e1.
To view E1 or T1 statistics for a layer, specify the controller type, e1 or ds1.
To view the configuration for a controller or all controllers in a layer, omit the controller
type.
Field descriptions
Description—Text description or alias if configured for the interface
BERT test—Number of current test and total number of tests
Test interval—Length of the BERT test
status—Sync (controller is synchronized with remote device) or NoSync (controller
is not synchronized with remote device
Sync count—Number of times the pattern detector synchronized with the incoming
data pattern