3.3 Application

3.3.1. Setups and Functions

3.3.1.1. Creating Setups
3.3.1.2. Mode of operation
© 2002 Carlo Gavazzi Industri A/S. All rights reserved
Values
A1..P8
W1..Z8
A1..P8
W1..Z8
-,/,\
AND, OR, XOR
A1..P8
W1..Z8
-,/,\
Navigating
For jumbing between the individual fields, press the Tab-key (forward) or the Alt- and Tab-keys
(backwards)
Adding
All fields in a logic setup must be filled in, ie all 4 components must be available. Any number of
setups can be selected, and gaps are allowed.
To add a function, place the cursor in any field in the row. Depending on the component, press a
letter or number key.
Changing
Changes are made in the same way as additions: place the cursor in the field "Function" and
overwrite the old value with the new value.
Deleting
The entire logic row can be deleted by placing the cursor in the field "Function" and press the
Delete-key or the space bar.
The in- and outputs can be channel addresses (A1 to P8) or flags (W1 to Z8).
Depending on the inputs or logic setup (result of the function), the output is set in each bus cycle
(max. all 134 ms). This means that the output assumes the value "0" when the setup is not ful-
filled and the value "1" when the setup is fulfilled.
The three logic functions correspond to the mathematical functions AND, OR and XOR (exclusive
of OR).
AND
The output is always "1", when both inputs are "1".
OR
The output is always "1", when one or both inputs are "1".
XOR
The output is "1", when only one of the two inputs are "1".
Description
Channel or flag whose status is to be changed
Channel or flag causing the first part of the
conditions for the change in output status
The logic operand connection the two inputs
Channel or flag causing the second part of the
conditions for the change in output status
October 2002
October 2002
October 2002
October 2002
October 2002
(1)
Abb.
A
E1
Fkt
E2
69

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for CARLO GAVAZZI G3800 X015 - CONFIGURATION SOFTWARE

This manual is also suitable for:

G 3800 x015

Table of Contents