G 3800 X015 Configuration Software
t
: The real-time clock activates the channel at the pre-defined time without affecting the input channel.
1
t
: By activation of the input, the output switches off directly.
2
t
: By activating the input once more, the output switches on again.
3
t
: At the set Switch off time, the input is always deactivated.
4
t
: The output can always be activated againg through the output.
5
Application Example
Task:
Solution:
Object
In-/outputs
Relay output
Switch
Configuration of Master Generator
Toggle switch function Light control
© 2002 Carlo Gavazzi Industri A/S. All rights reserved
A lamp is to be switched on and off by means of a switch.
Use for example the universal input module to provide the input signal and configure one of the
inputs for address A1. Assign the same address to one of the outputs of a relay module. Finally,
configure channel A1 in the Master Generator as a toggle switching function.
Function
Outdoor lamp
Light switch
Channel
A1
A1
A1
October 2002
21