1-17. DC Current Specifications

Range
0 to 3.29999 mA
0 to 32.9999 mA
0 to 329.999 mA
0 to 2.19999 A
0 to 11 A
0 to 11 A
[1]
The actual voltage compliance (Vc) is a function of current output (Io), and is given by the formula:
Vc = -5.05*Io+4.67. The highest compliance voltage is limited to 4.5 V.
[2]
The actual voltage compliance (Vc) is a function of current output (Io), and is given by the formula:
Vc = -0.588*Io+4.69. The highest compliance voltage is limited to 4.5 V.
[3]
The actual voltage compliance (Vc) is a function of current output (Io), and is given by the formula:
Vc = -0.204*Io+4.75. The highest compliance voltage is limited to 4.3 V.
Ranges
0 to 3.29999 mA
0 to 32.9999 mA
0 to 329.999 mA
0 to 2.19999 A
0 to 11 A
0 to 11 A
1-12
Absolute Uncertainty,
tcal ± 5 C
± (% of output + A)
90 days
0.010
0.05
0.013
0.008
0.25
0.01
0.008
3.3
0.01
0.023
44
0.03
0.038
330
0.06
5725A Amplifier
0.03
330
0.04
Bandwidth
0.1 to 10 Hz
p-p
20 nA
200 nA
2000 nA
20 A
200 A
5725A Amplifier
± 25 ppm of output + 200 nA
Resolution
1 year
0.05
0.01 A
0.25
0.1 A
3.3
1 A
44
10 A
330
100 A
330
100
Noise
Maximum
Compliance
Inductive
Voltage
Load
4.5 V
1 H
4.5 V
200 H
[1]
4.5 to 3.0 V
200 H
[2]
4.5 to 3.4 V
200 H
[3]
4.3 to 2.5 V
200 H
4 V
400 H
Bandwidth
10 to 10 kHz
rms
200 nA
2.0 A
20 A
1 mA
10 mA
2 mA