Closed fixes summary
LS creation, ports added in incorrect order when slot 1, then slot 12
added to Right Hand Side.
For VE-VEx connection, in Routing Domain IDs dialog box, unable to
move the phantom switch in the edge switch to the selected switches
table.
Maximum Historical Event values are not getting migrated from 10.1.x
to 10.3.0 in Event Storage category of Options dialog box,
Discovery status for VF enabled switch is not getting updated in the
Discovery dialog box after changing its credentials from v1 to v3.
Unable to configure user selected event types for a new user, when
logging in as a new user, all events are displayed in selected events
column in local/remote client.
Yellow banner displayed in ACL tab of Add LAG dialog box is not
according to FS.
Yellow banner displayed in ACL tab of Edit Port dialog box [LAG
member] is not according to Functional Specification document.
Destination and Destination port columns are blank in Historical Reports
for 10 GE Ports.
Accept changes is not working, support save did not complete even
after 5 hours, Remote Client is blank.
Scheduled configuration for Technical support save is not migrating
from DCFM Professional to Enterprise.
The Active TI zone is not shown as Active in the zone DB tab.
Encryption switch/blade public certs exported during setup are actually
CSR and needs to be signed before the switches can connect to the
keyvault.
Zone details missing in zone compare.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
Solution
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Domain ID for the phantom switch can
be configured in CLI.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Configure Maximum Historical Event
values after migration in
SAN-->Options-->Event Storage.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Generate Historical Reports for the TE
ports at port level and switch level.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Reconfigure the scheduling option
after migration.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Use
CLI or Web Tools to know the TI zone
status.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Use
the CLI command to export the self
signed pub cert: cryptocfg --export
-scp -KACcert [scp server address]
[scp server login id] [scp server path]
Fixed in DCFM 10.4.0.