HP 1606 Release Note page 36

Hp storageworks b-series data center fabric manager enterprise, professional plus, and professional 10.4.5a release notes (5697-
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

Closed fixes summary
Unable to create Single side tunnel when Uncommitted is checked in
Add FCIP Circuit dialog box.
Auto enclosure is not created in the Fabric view after discovering Host
and wrong fabric WWN is shown in the Host view.
Activating a configuration without loading to Right Hand Side (PDCM
Matrix) fails and NPE is thrown in the Client.
Fault Management : Master log event count is incremented with the
old source name even when the switch name is changed.
Seed Switch failover does not happen to Switch 3 in pure EOS fabric
as DCFM does not release the NMRU link of Switch 2.
An additional entry of WWN is being added in the zones table when
a CNA is added to a Zone.
View Utilization menu item is disabled in Fabric view when the dis-
covered Host is deleted
Discovery dialog box is not showing the status "SNMP communication
failed. SNMP credentials may be invalid" when the user fails to provide
the configured Auth\ priv passwords in DCFM.
Delete of a logical switch failed, server errors about moving port from
and to the same FID.
When context name field is empty, SNMPv3 trap forwarding is failed.
After migration from 10.1.x Enterprise Edition to 10.3.1 Enterprise
Edition, Mi10k is not getting manageability in Mixed fabric if dis-
covered through APIuser in DCFM 10.1.x
36
Solution
Workaround prior to upgrade: Check
the Committed option and able to
create the tunnel
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Load
the configuration in the Right hand
side and then activate the
configuration.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: By
removing the Extra entry of WWN
from the Zones table, user can
activate the Zone configuration
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Select
any Fabric or Switch in the Device
Tree
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Provide all the configured v3
credentials when discovering the
switch.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Fill any
value in the context name field. - If the
correct user name, Auth/Priv protocol
and password are set, the trap will
be forwarded to the destination.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: To get
manageability after migration, Go to
SNMP tab for Mi10k switch in Edit
dialog box and check the "Configure
for Intrepid 10k" checkbox.
Fixed in DCFM 10.4.0.